设为首页 电子邮箱 联系我们

本刊最新招聘信息请见“通知公告”!  本刊投稿系统试运行中,欢迎投稿!如投稿有问题,可直接将稿件发送至zgyy8888@163.com

 

主管单位:中华人民共和国   

国家卫生健康委员会

主办单位:中国医师协会
总编辑:
杨秋

编辑部主任:吴翔宇

邮发代号:80-528
定价:28.00元
全年:336.00元
Email:zgyy8888@163.com
电话(传真):010-64428528;
010-64456116(总编室)

                  

过刊目录

2021 年第 3 期 第 16 卷

高原地区高血压病患者诊室血压和家庭自测血压及24 h动态血压的达标率一致性分析

Consistency analysis of attainment rate of clinic blood pressure, home pressure and 24 h ambulatory blood pressure in patients with hypertension in plateau area

作者:卢景华马淑媗祁琛虹

英文作者:Lu Jinghua Ma Shuxuan Qi Chenhong

单位:青海省心脑血管病专科医院心电学科,西宁810012

英文单位:Department of Electrocardiology Qinghai Province Cardiovascular and Cerebrovascular Disease Hospital Xining 810012 China

关键词:高原地区高血压病;诊室血压;家庭自测血压;24h动态血压;血压达标率

英文关键词:Hypertensioninplateauarea;Clinicbloodpressure;Homebloodpressure;24hambulatorybloodpressure;Bloodpressureattainmentrate

  • 摘要:
  • 目的 研究分析高原地区高血压病患者诊室血压、家庭自测血压及24 h动态血压的血压达标率一致性。方法 选取201710月至201912月青海省心脑血管病专科医院收治的高原地区高血压病患者186例为研究对象,用诊室血压、家庭自测血压及24 h动态血压3种方法监测患者血压,比较不同血压监测方法的血压达标率,并分析血压达标率的一致性。结果 24 h动态血压监测的血压达标率明显高于诊室血压和家庭自测血压[35.5%66/186)比20.4%38/186)、16.1%30/186)],差异均有统计学意义(均P0.05)。诊室血压达标率与24 h动态血压达标率具有一致性(Kappa=0.151P=0.001),家庭自测血压达标率与24 h动态血压达标率具有一致性(Kappa=0.194P0.001),诊室血压达标率与家庭自测血压达标率不具有一致性(Kappa=0.043P=0.283)。结论 不同血压监测方法监测高原地区高血压病患者血压,其中24 h动态血压达标率最高,与诊室血压和家庭自测血压达标率均具有一致性。

  • Objective To investigate the consistency of attainment rate of clinic blood pressure, home blood pressure and 24 h ambulatory blood pressure among patients with hypertension in plateau area. Methods From October 2017 to December 2019 186 patients with plateau area hypertension admitted to Qinghai Province Cardiovascular and Cerebrovascular Disease Hospital were enrolled. The clinic blood pressure (CBP), home blood pressure (HBP) and 24 h ambulatory blood pressure (ABP) were used to monitor patients blood pressure. The attainment rates of different monitoring methods were compared. The consistency of the three methods was analyzed. Results Attainment rate of ABP was higher than that of CBP and HBP35.5%66/186 vs 20.4%38/186, 16.1%30/186)](both P0.05. Attainment rate of CBP was consistent with that of ABP (Kappa=0.151, P=0.001), attainment rate of HBP was consistent with that of ABP (Kappa=0.194P0.00), but attainment rate of CBP was not consistent with that of HBP (Kappa=0.043, P=0.283). Conclusion Among different blood pressure monitoring methods in patients with hypertension in plateau area, ABP has the highest attainment rate, which is consistent with that of CBP and HBP at a certain degree.

copyright 《中国医药》杂志编辑部
地址:北京市朝阳区安贞路2号首都医科大学附属北京安贞医院北楼二层
电话:010-64456116 传真:010-64428528 邮编:100029 Email: zgyy8888@163.com
网址:www.chinamedicinej.com 京ICP备2020043099号-3

当您在使用本网站投稿遇到困难时,请直接将稿件投送到编辑部邮箱zgyy8888@163.com。







安卓


苹果

关闭