设为首页 电子邮箱 联系我们

本刊最新招聘信息请见“通知公告”!  本刊投稿系统试运行中,欢迎投稿!如投稿有问题,可直接将稿件发送至zgyy8888@163.com

 

主管单位:中华人民共和国   

国家卫生健康委员会

主办单位:中国医师协会
总编辑:
杨秋

编辑部主任:吴翔宇

邮发代号:80-528
定价:28.00元
全年:336.00元
Email:zgyy8888@163.com
电话(传真):010-64428528;
010-64456116(总编室)

                  

过刊目录

2018 年第 3 期 第 13 卷

血管内超声对腹主动脉瘤腔内修复术中Ⅰ型内漏的诊断价值

Diagnostic value of intravascular ultrasound for type Ⅰ endoleak in endovascular repair of abdominal aneurysm

作者:张腾飞唐小斌杨耀国吴小凡何楠王晓娜陈忠

英文作者:

单位:100029首都医科大学附属北京安贞医院血管外科

英文单位:

关键词:

英文关键词:

  • 摘要:
  • 目的    探讨血管内超声(IVUS)对腹主动脉瘤腔内修复术(EVAR)中Ⅰ型内漏的诊断价值。方法    选取2014年7月至2017年2月首都医科大学附属北京安贞医院血管外科收治的行EVAR的肾下性腹主动脉瘤患者16例,男11例、女5例,平均年龄(66±3)岁,术中数字减影血管造影(DSA)显示存在内漏,用IVUS观察覆膜支架的贴壁情况;记录内漏发生的位置。结果    16例患者均顺利完成EVAR及IVUS观察,成功率100%。DSA诊断11例患者为Ⅰ型内漏,IVUS发现近端支架贴壁不良,10例为Ⅰ型内漏,1例考虑膜漏(Ⅳ型内漏)可能性大;4例患者DSA无法确定内漏类型,怀疑Ⅰ型内漏,IVUS考虑膜漏(Ⅳ型内漏)。1例患者DSA发现内漏,IVUS不能判断是否贴壁良好,通过CODA球囊后扩张发现内漏消失。随访3~6个月,均未出现内漏。受试者工作特征曲线显示IVUS发现支架贴壁不良与内漏发生高度相关(P=0.027)。结论    IVUS显示贴壁不良与DSA发现内漏符合率很高,IVUS能够比较准确地发现支架贴壁不良的位置,间接更好地明确内漏的位置。

  • Objective    To investigate the value of intravascular ultrasound(IVUS) in diagnose of type Ⅰ endoleak in endovascular aneurysm repair(EVAR) of abdominal aortic aneurysm. Methods    Sixteen patients, including 11 males and 5 females with abdominal aneurysm undergoing EVAR were enrolled from July 2014 to February 2017 in Beijing Anzhen Hospital, Capital Medical University; the average age was (66±3)years. Intraoperative digital subtraction angiography(DSA) showed endoleaks in all patients; IVUS was used to observe the position of stent graft. Results    All 16 patients successfully completed EVAR and IVUS; the success rate was 100%. Eleven patients were diagnosed of type Ⅰ endoleak by DSA; IVUS showed proximal stent malapposition, 10 cases were confirmed as type Ⅰ endoleak and 1 case was suspected membranous leak(type Ⅳ endoleak). Four patients were suspected type Ⅰ endoleak by DSA and they were suspected membranous leak(type Ⅳ endoleak) by IVUS. One patient with endoleak diagnosed by DSA could not be confirmed by IVUS, and the endoleak disappeared after CODA ballon dilation. No endoleak occurred in 3-6 months after operation. The receiver operating characteristic curve showed a high correlation between stent malapposition disgnosed by IVUS and the occurrence of endoleak(P=0.027). Conclusions    tent malapposition diagnosed by IVUS shows a high coincidence with endoleak disgnosed by DSA; IVUS can show the position of stent graft to help accurately find the location of endoleak.

copyright 《中国医药》杂志编辑部
地址:北京市朝阳区安贞路2号首都医科大学附属北京安贞医院北楼二层
电话:010-64456116 传真:010-64428528 邮编:100029 Email: zgyy8888@163.com
网址:www.chinamedicinej.com 京ICP备2020043099号-3

当您在使用本网站投稿遇到困难时,请直接将稿件投送到编辑部邮箱zgyy8888@163.com。







安卓


苹果

关闭